Renewable Energy

Renewable energy such as solar panels and heat pumps are permitted development by virtue of Part 14 of the Town and Country Planning (General Permitted Development) (England) Order 2015

To be permitted development, it must meet the criteria in the table below. If it does not meet the criteria, a planning application is required. You can seek confirmation that your renewable energy project is lawful by submitting a lawful development certificate. In some instances, prior approval is required. Details of how to submit a prior approval can be found here.

To understand if your property is listed or in a conservation area.

Solar Panels

  • Must not be on or within curtilage of a listed building
  • Must not unreasonably or unduly affect the external appearance or amenity of the area
  • Must be removed when no longer used

Domestic (dwellings and flat buildings)

On a pitched roof

On a flat roof1

On a wall

Stand-alone1

  • Max 0.2m projection from the roof
  • Not above the highest part of the roof
  • Max 0.6m projection from the roof
  • Max 0.2m projection from the wall
  • Not facing the road in a conservation area
  • Max of 1
  • Max 4m height (or 2m in a conservation area and forward of the dwelling)
  • Min 5m from the boundary
  • Max 3m dimension and 9m2 area

Non-domestic

On a pitched roof1

On a flat roof1

On a wall

Stand-alone1

  • Max 0.2m projection from the roof
  • Min 1m from edge of roof
  • Max 1m projection from the roof
  • Min 1m from edge of roof
  • Max 0.2m projection from the roof
  • Min 1m from edge of wall
  • Not facing the road in a conservation area
  • Max of 1
  • Max 4m height (or 2m in a conservation area and forward of the dwelling)
  • Min 5m from the boundary
  • Max 3m dimension and 9m2 area

1Prior approval is required where sited in a conservation area and/or facing a road.

Heat Pumps

  • Must not be on or within curtilage of a listed building
  • Must be for heating only
  • Must not unreasonably or unduly affect the external appearance or amenity of the area
  • Must be removed when no longer used
  • Air conditioning units that are not ground, water or air source heat pumps require planning permission.

Domestic (dwellings and flat buildings)

Air Source

Water Source

Ground Source

  • Accords with the installation requirements and Section 3 of the MCS Planning Standards
  • Max 1 pump or turbine
  • Max volume of 0.6m3
  • Min 1m from the boundary
  • Min 1m from edge of flat roof
  • Not on a pitched roof
  • Not on a wall facing a road or above the ground floor
  • Not forward of the dwelling or facing the road in a conservation area
  • Max 45kW
  • Max 45kW

Non-domestic

  • Max 0.2m projection from the wall
  • Not facing the road in a conservation area
  • Max 45kW
  • Max area of 0.5 ha
  • Max 45kW
  • Max 1